Infectious Disease

169 Results Found

Active filters:

HTLV-I/II ELISA 4.0 (RUO)

The MPD HTLV-I/II ELISA 4.0 is a direct sandwich immunoassay that utilizes a combination of recombinant proteins and a tri-fusion recombinant protein labeled with horseradish peroxidase. The MPD HTLV-I/II ELISA 4.0 is intended as a semi-qualitative enzyme-linked immunosorbent assay for the detection of antibodies to both HTLV-I and HTLV-II found in human serum or plasma.

HBeAg ELISA 4.0 (RUO)

The MPD HBeAg ELISA 4.0 is a double antibody sandwich immunoassay that utilises monoclonal antibodies specific to HBeAg. The presence of HBeAg in a specimen is detected by a secondary antibody conjugated to horseradish peroxidase. It is intended as a qualitative enzyme-linked immunosorbent assay for the detection of HBeAg found in human serum or plasma. It is intended as a first line screening, requiring repeat testing of initially reactive specimens and confirmation of repeat reactive specimens by supplementary assays.

HBsAg ELISA 4.0 (RUO)

The MPD HBsAg ELISA 4.0 is a double antibody sandwich immunoassay that utilises monoclonal antibodies speci fic to HBsAg. The presence of HBsAg in a specimen is detected by a secondary antibody conjugated to horseradish peroxidase. It is intended as a qualitative enzyme-linked immunosorbent assay for the detection of HBsAg found in human serum or plasma. It is intended as a first line screening, requiring repeat testing of initially reactive specimens and confi rmation of repeat reactive specimens by supplementary assays.

HIV Ag/Ab Combo ELISA 4.0 (RUO)

The MP DIAGNOSTICS (MPD) HIV Ag/Ab Combo ELISA 4.0 is an enzyme-linked immunosorbent assay (ELISA) intended for qualitative detection of antigens and/or antibodies to Human Immunodeficiency Viruses (HIV) type 1 (group M - O) and/or type 2 in human serum or plasma samples.

HIV Ag/Ab Combo ELISA 4.0

The MP DIAGNOSTICS (MPD) HIV Ag/Ab Combo ELISA 4.0 is an enzyme-linked immunosorbent assay (ELISA) intended for qualitative detection of antigens and/or antibodies to Human Immunodeficiency Viruses (HIV) type 1 (group M - O) and/or type 2 in human serum or plasma samples.

HIV-1 Blot 1.3 (CE)

The MP Diagnostics HIV-1 BLOT 1.3 is a qualitative enzyme immunoassay for the in-vitro detection of antibodies to HIV-1 in human serum or plasma. It is intended for use as a more specific supplemental test on human serum or plasma specimens found repeatedly reactive using screening procedures such as the Enzyme-Linked Immunosorbent Assay (ELISA).

HIV-1 Blot 1.3 (RUO)

The MP Diagnostics HIV-1 BLOT 1.3 is a qualitative enzyme immunoassay for the in-vitro detection of antibodies to HIV-1 in human serum or plasma. This kit is supplied for research purposes only. It is not intended for use in the diagnosis or prognosis of diseases. In particular, this test cannot be used to evaluate blood specimens for the purpose of donor screening, or as a confirmatory diagnostic.

HIV-2 Blot 1.2

The MP Diagnostics HIV-2 BLOT 1.2 is a qualitative enzyme immunoassay for the in-vitro detection of specific antibodies to HIV-2 in human serum or plasma. The MP Diagnostics HIV-2 BLOT 1.2 is intended for use as a more specific test on human serum or plasma specimens found to be repeatedly reactive using screening procedures like the Enzyme-Linked Immunosorbent Assay (ELISA).

HIV-2 Blot 1.2 (RUO)

The MP Diagnostics HIV-2 BLOT 1.2 is a qualitative enzyme immunoassay for in-vitro detection of specific antibodies to HIV-2 in human serum or plasma. This test kit is supplied for research purposes only. It is not intended for use in the diagnosis or prognosis of disease. In particular, this test cannot be used to evaluate blood specimens for the purposes of donor screening or as a confirmatory diagnostic.

HIV Blot 2.2 (CE)

The MP Diagnostics HIV BLOT 2.2 is a qualitative enzyme immunoassay for the in vitro detection of antibodies to human immunodeficiency virus type 1 (HIV-1) and type 2 (HIV-2) in human serum or plasma. It is intended for use as a more specific supplemental test on human serum or plasma specimens found repeatedly reactive using screening procedures such as the Enzyme-Linked Immunosorbent Assay (ELISA).

HIV Blot 2.2 (RUO)

The MP Diagnostics (MPD) HIV BLOT 2.2 is a qualitative enzyme immunoassay for the in-vitro detection of antibodies to human immunodeficiency virus type 1 (HIV-1) and type 2 (HIV-2) in human serum or plasma. This test kit is supplied for Research Use Only. It is not intended for use in the diagnosis or prognosis of disease.

HIV Blot 2.2 (China)

The MP Diagnostics HIV BLOT 2.2 is a qualitative enzyme immunoassay for the in vitro detection of antibodies to human immunodeficiency virus type 1 (HIV-1) and type 2 (HIV-2) in human serum or plasma. It is intended for use as a more specific supplemental test on human serum or plasma specimens found repeatedly reactive using screening procedures such as the Enzyme-Linked Immunosorbent Assay (ELISA).

HTLV Blot 2.4 (CE)

The MP Diagnostics HTLV BLOT 2.4 is a qualitative enzyme immunoassay for the in vitro detection of antibodies to HTLV-I and HTLV-II in human serum or plasma. It is intended for use as a more specific supplemental test on human serum or plasma specimens found repeatedly reactive using screening procedures like the Enzyme-Linked Immunosorbent Assays (ELISA).

HCV Blot 3.0 (CE)

The MP Diagnostics HCV BLOT 3.0 is a qualitative enzyme immunoassay for the in vitro detection of antibodies to HCV in human serum or plasma. It is intended for use as a more specific supplemental test on specimens found repeatedly reactive using specific procedures such as ELISA.

HCV Blot 3.0 (RUO)

The MP Diagnostics (MPD) HCV BLOT 3.0 is a qualitative enzyme immunoassay for the in vitro detection of antibodies to HCV in human serum or plasma. This kit is supplied for research use only. It is not intended for use as in the diagnosis or prognosis of disease. In particular, the test cannot be used to evaluate blood specimens for the purpose of donor screening, or as a confirmatory diagnostic.

Helico Blot 2.1 (CE)

The MP Diagnostics HELICO BLOT 2.1 Western Blot kit assay is a qualitative assay for the detection of IgG antibodies to Helicobacter pylori (H. pylori) in human serum or plasma, with the added indication of current status. It is an improved version of HELICO BLOT 2.0 where in addition to bacterial lysate, there is a recombinant antigen with high predictive value for the indication of current H. pylori . The product is intended for use as a serological test for the detection of both current and past with H. pylori. Unlike an ELISA, the MP Diagnostics HELICO BLOT 2.1 allows for the detection of antibodies to specific proteins of H. pylori, including antigens associated with pathology such as CagA and VacA.

Helico Blot 2.1 (RUO)

The MP Diagnostics (MPD) HELICO BLOT 2.1 Western Blot kit assay is a qualitative assay for the detection of IgG antibodies to Helicobacter pylori (H. pylori) in human serum or plasma, with the added indication of current status. It is an improved version of HELICO BLOT 2.0 where in addition to bacterial lysate, there is a recombinant antigen with high predictive value for the indication of current H. pylori . The product is intended for use as a serological test for the detection of both current and past with H. pylori. Unlike an ELISA, the MP Diagnostics HELICO BLOT 2.1 allows for the detection of antibodies to specific proteins of H. pylori, including antigens associated with pathology such as CagA and VacA. This kit is supplied for research purposes only. It is not intended for use in the diagnosis or prognosis of disease. In particular, this test cannot be used to evaluate blood specimens for the purpose of donor screening, or as a confirmatory diagnostic.

HIV-1/2 ELISA 4.0 (CE)

The MP Diagnostics (MPD) HIV-1/2 ELISA 4.0 is an enzyme-linked immunosorbent assay (ELISA) intended for the detection of antibodies to Human Immunodeficiency Viruses (HIV) type 1 (group M - O) or type 2 in human serum or plasma samples. The assay can be utilized for screening of blood donors and/or as an aid in the diagnosis of clinical conditions related to infection with HIV-1 and/or HIV-2 - the etiological agents of the acquired immunodeficiency syndrome (AIDS).

HIV-1/2 ELISA 4.0 (RUO)

The MP Diagnostics (MPD) HIV-1/2 ELISA 4.0 is an enzyme-linked immunosorbent assay (ELISA) intended for the detection of antibodies to Human Immunodeficiency Viruses (HIV) type 1 (group M - O) or type 2 in human serum or plasma samples. This kit is supplied for research purposes only.

HTLV-I/II ELISA 4.0 (CE)

The MP Diagnostics HTLV I/II ELISA 4.0 is an enzyme-linked immunosorbent assay intended for the detection of antibodies to Human T-cell Lymphotropic Virus type 1 (HTLV-I) and type 2 (HTLV-II) in human serum or plasma. It is intended as a screening test, requiring repeat testing of initially reactive specimens.